13.1.4 Environment
Indoor/Outdoor
Installation temperature and operating temperature:
-40°C (-40°F)/+60°C (140°F)
Surge immunity: up to 2 kV line to line, up to 4 kV
between line and earth (EN61000-4-5 level 4)
13.1.5 Certications
ATEX (EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-
31: 2009)
-
b
II 2 G Ex d IIB T6 Gb Ta -40°C to +60°C or
-
b
II 2 G Ex d IIC T6 Gb Ta -20°C to +60°C or Ta
-40°C to +60°C and/or
-
b
II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C
IECEX (IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC
60079-31: 2008)
- Ex d IIB T6 Gb Ta -40°C to +60°C or
- Ex d IIC T6 Gb Ta -20°C to +60°C or Ta -40°C to
+60°C and/or
- Ex tb IIIC T85°C Db Ta -40°C to +60°C
IP66/IP67 (EN60529:1991/A1 2001)
13.1.6 Accessories
OCTEX3/4C Cable gland with gasket EX
3/4" NPT, unarmoured cable
IECEX-ATEX-GOST
OCTEXA3/4C Cable gland with gasket EX
3/4" NPT, armoured cable
IECEX-ATEX-GOST
OCTEXB3/4C Barrier cable gland 3/4" NPT,
unarmoured cable IECEX-ATEX-
GOST
OCTEXBA3/4C Barrier cable gland 3/4" NPT,
armoured cable IECEX-ATEX-
GOST
OCTEX3/4 Cable gland with gasket EX
3/4" NPT, unarmoured cable
ATEX
OCTEXA3/4 Cable gland with gasket EX
3/4" NPT, armoured cable ATEX
13.1.7 Brackets and adapters
MHXWBS AISI 316L stainless steel wall
bracket
MPXCW AISI 316L stainless steel corner
adapter module
MPXCOL AISI 316L stainless steel pole
adapter module
MHXWFWCA Ball joint in AISI316L stainless
steel