Page 84 MNVADCJ01_0543
7"**%, remove position 5
7#**%, 5 seconds dwell time between one position and the next
, start the patrol sequence.
6.9.6 Auxiliary re lays
-5 (1÷8): activate relay X
.5 (1÷8): deactivate relay X.
6.9.7 Lenses
: autofocus on
: autoiris on
6.9.8 Return pos ition
It is possible to configure the dome to move automatically to a “return position” after a set interval of inactivity.
7$555, where X consists of:
• the first two digits show the return position to be considered (only positions from 1 to 99 are allowed;
positions from 100 to 128 can not be selected)
• the third digit shows the return time:
0: 10 seconds, 1: 20 seconds, 2: 30 seconds,
3: 40 seconds, 4: 1 minute, 5: 2 minutes,
6: 5 minutes, 7: 10 minutes, 8: 20 minutes,
9: 40 minutes
For example, the code
7$"!& sets the dome to return to position 21 after 5 minutes of
inactivity.
6.9.9 Other spec ial codes
7$**: text shown/not shown (toggle)
7%**: Backlight compensation on/off (toggle)
7)))): reset internal memory of dome
Comments to this Manuals